McKesson Radiology 12.2 Produced in Cork, Ireland – Confidential and Proprietary 1.0, 27 June, 2016 Page 8 Chapter 3 – Understanding McKesson Radiology Logging on to McKesson Radiology 1. Press Ctrl + Alt + Delete 2. Enter your Username and Password 3. McKesson Radiology is started and your default study list is displayed. Non-reporting users can download McKesson Radiology Station Lite for improved system performance that includes a basic toolset for non-diagnostic viewing. McKesson Radiology Station Lite provides access to the same images, reports and pertinent patient information available to all McKesson Radiology users.

This guide is valid for Clinical Reference Viewer 1.1 for McKesson Radiology 12.4 and its service pack and expansion pack releases.

Download

The following sections describe the Clinical Reference Viewer system requirements, and how to troubleshoot problems related to starting the application:


Workstation requirements

The system requirements to use Clinical Reference Viewer on a workstation are described in the following table:

ItemWorkstation requirement
Network

Minimum network connection:

  • LAN: 100 Mbps, with latency of less than 5 msec
  • WAN: 10 Mbps, with maximum round-trip latency of 50 msec
Operating system
  • Windows® 10 (64-bit)

  • Note: To run Clinical Reference Viewer on Windows® 10, use Internet Explorer® 11. See Running Clinical Reference Viewer on Windows® 10.
  • Windows® 7 SP1 (64-bit or 32-bit)
  • Mac® OS X® 10.9.3
  • Mac® mini OS X® 10.7.5
Screen resolution

Minimum 800 x 600 screen resolution in 24-bit or 32-bit color mode

Web browser
  • For Windows® 10: Internet Explorer® 11
  • For Windows® 7:
    • Internet Explorer® 11, 10, or 9
    • Mozilla Firefox® 39 or 38
    • Google Chrome 43 or 41
  • For OS X® 10.9.3: Apple® Safari® 7.0.3
  • For OS X® 10.7.5: Apple® Safari® 6.1.6
Note:
  • Ensure that Javascript and browser cookie support are enabled and that pop-up blockers are disabled in the Web browser you are using to access Clinical Reference Viewer. For details, refer to the applicable Web browser documentation.
  • Only the 32-bit version of Internet Explorer® is supported.
Media player, to play voice clips
  • Windows Media® Player 12.0
  • Apple® QuickTime® 10.3 for OS X® 10.9.3
  • Apple® QuickTime® 10.1 for OS X® 10.7.5

Tablet requirements

The system requirements to use Clinical Reference Viewer on a tablet are described in the following table:

Tablet requirement
RAMMinimum 500 MB
Tablet and operating system
  • Samsung Galaxy Tab® 3 with Android OS 4.1.x - 4.3 or 4.4
  • Google Nexus 7 with Android OS 4.1.x - 4.3 or 4.4
  • Microsoft® Surface Pro 2 with Windows® 10
  • Apple® iPad® 4 with iOS® 7
  • Apple® iPad mini with iOS® 7 or 8
Screen resolution

Minimum 600 pixels horizontal screen resolution

NetworkMinimum network connection:
  • 3G
    -or-
  • WiFi
Web browser
  • For Android OS 4.1.2: Google Chrome 40
  • For Android OS 4.4.2 and 4.4.3: Google Chrome 40, 42, or 43
  • For Windows® 10: Internet Explorer® 11
  • For iOS® 7: Apple® Safari® 7
  • For iOS® 8: Apple® Safari® 8

Note: Ensure that Javascript and browser cookie support are enabled and that pop-up blockers are disabled in the Web browser you are using to access Clinical Reference Viewer. For details, refer to the applicable Web browser documentation.

Note: Clinical Reference Viewer is part of the McKesson Radiology image-viewing platform, intended to address the needs of report-centric PACS users interested in viewing images as references on a wide variety of computing platforms. To meet this need, Clinical Reference Viewer is designed to comply with World Wide Web Consortium (W3C®) standards such that any compliant Internet browser may provide basic Clinical Reference Viewer functionality.

We support Clinical Reference Viewer running on a number of Internet browsers, specifically those compliant with HTML 4.01, Javascript™ 1.5, and CSS 1.0, accessible via HTTP 1.1, with TLS 1.2.

Due to the large number and continual evolution of desktop, laptop, mobile-browser and OS environment combinations, we reserve the right to defer to future McKesson Radiology releases the resolution of issues found in environments not listed in the representative examples above.


When you log in to Clinical Reference Viewer, the following messages may be displayed on the Login page:

If this message is displayed... Then...

Your login failed. Please try again or contact an administrator for assistance.

One of the following conditions may apply:

  • Your password has expired. See Changing your password.
  • You have been locked out of your account.
  • Your account has expired.
  • Access to the system is denied.
  • You are not authorized to log in to Clinical Reference Viewer on the current workstation.
  • A server or system error has occurred.

If changing your password does not resolve the issue, do one of the following:

  • Close the Clinical Reference Viewer Login page, wait a few minutes, and then restart Clinical Reference Viewer.
  • Contact your system administrator.
The user name and password combination you have entered is incorrect. Please try again.

Clinical Reference Viewer cannot match the user name to the password you specified. Do the following:

  1. In the User name field, ensure that you specified the correct user name. Retype the name if necessary.
  2. In the Password field, retype the password.

Javascript is disabled in your browser. In order for McKesson Radiology Clinical Reference Viewer to function, you need to enable Javascript.

Javascript is not enabled in your Web browser. To ensure that Clinical Reference Viewer is displayed correctly, enable Javascript.

For details, refer to the applicable Web browser documentation.

Cookies are disabled. Please enable cookies in your browser to continue.

Note: This message is displayed in a message dialog box.

Cookies are not enabled in your Web browser. To ensure that you can access all Clinical Reference Viewer functionality, enable cookies.

For details, refer to the applicable Web browser documentation.


  1. On the Login page, click Change password.
    The Change your password page is displayed.
  2. In the User Name field, type your user name.
  3. In the Enter Current Password field, type your current password.
  4. In the Choose a New Password field, type a new password.
    Note: For security reasons, specific password complexity requirements may be configured for your site. For details, contact your system administrator.
  5. In the Confirm your New Password box, retype your new password.
  6. Click Save.
    The following messages may be displayed:
  7. If this message is displayed... Then...
    The user name and old password combination you have entered is incorrect. Please try again.

    The user name and current password combination you entered is incorrect. Do the following:

    1. In the User Name field, ensure that you specified the correct user name.
    2. In the Enter Current Password box, ensure that you specified the correct password. Retype the new password if necessary.
    The password confirmation does not match. Please enter your new password again.

    Your new password could not be confirmed, as the confirmation password you specified does not match the new password. Do the following:

    1. In the Choose a New Password box, ensure that you specified the correct password. Retype the new password if necessary.
    2. In the Confirm your New Password box, type the password exactly as specified in the Choose a New Password box.
    3. Click Save.
    Your password did not meet the minimum password requirements. Please re-enter your password or contact your administrator for assistance.

    Your site may be configured to recognize certain password complexity requirements. For example, a requirement may be that a password can contain no more than 10 alphanumeric characters.

    Note: Complexity requirements for passwords are site-dependent. Contact your system administrator for details.

    A problem occurred while trying to change your password. Please contact your administrator for further assistance.

    Your password cannot be changed due to a system error. Contact your system administrator.

    Note: This message may be displayed if you enter an invalid user name. In the User Name field, ensure that you entered the correct user name.

To run Clinical Reference Viewer on Windows® 10, use Internet Explorer® 11.

  1. Open Internet Explorer® 11.
    To locate Internet Explorer®, perform the following steps:
    1. In the Windows®Start menu, click All apps.
      The list of available applications is displayed.
    2. In the list, click Windows Accessories, and then click Internet Explorer.
      Internet Explorer® 11 is started.
  2. Navigate to the Clinical Reference Viewer login page.
  3. Log in to Clinical Reference Viewer.

Call the toll-free number for your region listed at: https://iwcrm.changehealthcare.com.

McKesson Radiology Station Disc is a portable solution that enables diagnostic images, the McKesson Radiology Station™ native DICOM. Uzli ventiliruemij fasad dwg. Standard quick viewer (i.e., DEFF, JPEG, TIFF) and/or diagnostic advanced viewer (DICOM) with a basic image manipulation toolset.

Flexible deployment • Deployment and usability options that address specific business challenges and user requirements. • Easy to implement, but sufficiently flexible and intelligent to follow end users as they move within, or even outside, a healthcare enterprise, retaining user preferences for each login, regardless of where they access the system.

• Various deployment alternatives that meet the requirements of different end users, including robust and feature rich tool-sets for power users and hospital staff. Advanced clinical applications • Change Healthcare Radiology Solutions brings advanced clinical workflows and associated quantitative analysis capabilities directly within the radiologist’s read-flow.

• 16 Advanced Visualization applications, tools and workflows that are essential for reading CT and MR exams are included at no cost. In addition, we offer over 30 applications, tools and workflows for Oncology, Neurology and Cardiology imaging for purchase.

Mckesson Radiology Viewer Download

Viewer

• Integrated Advanced Visualization can eliminate the need for dedicated specialized AV workstations and associated costs for customers, while reducing the cost of healthcare delivery. Radiology analytics • A powerful cloud-based analytics solution that offers the ability to interactively visualize and explore operational metrics, helping discover business improvement opportunities. The core solution is included at no additional software license fee. • Turns actionable and critical insights into data-driven decisions about how to run your business, such as discovering operational improvements and productivity outliers.

• Unlocks the real value of data: helping others discover opportunities for improvement, such as controlling costs and leveraging staff and modalities.

Mckesson Radiology Viewer Download Free

The following sections describe how to troubleshoot messages that may be displayed while you are installing, upgrading, or starting McKesson Radiology Station ™. Microsoft ® Internet Explorer ® is the recommended Web browser used to access McKesson Radiology Station ™. See for more information. • • • • • • • • • • • • • • • • • The following table describes how to troubleshoot the messages that may be displayed while you are installing or upgrading McKesson Radiology Station ™: Message Troubleshooting tip Install Failed: McKesson Radiology Station ™ Install was cancelled or an unexpected error occurred.

Mckesson Radiology Viewer Download Windows 10

Please click here to retry. Note: This warning message is common when you install McKesson Radiology Station ™ on Windows ® 7. To receive fewer warning messages, you can add the McKesson Radiology ™ launch page as a. If you are using Windows ® 7, and a security warning is displayed below the Internet Explorer ® toolbar, ensure that the following criteria are met: • The warning states: The website wants to install the following add-on.

Mckesson Radiology Viewer Download Mac

- and - • The warning states that the add-on is from McKesson Corporation. If both criteria are met, the McKesson Radiology Station ™ installation has not failed. Requests your permission to let an installation file access your system. To grant this permission: • Click the message. McKesson Radiology Station ™ continues to install. You are not authorized to install McKesson Radiology Station ™. Ensure that you have the authority to install McKesson Radiology Station ™: • If you are using Windows ® 7, you need to be a member of the Windows ® Administrators group.